Ransburg, Dynaflow, Programer's manual - introduction – Ransburg DynaFlow Programmers Manual User Manual

Page 45

Advertising
background image

Command T

ype (hex)

Response Or

Action From User Interface

Response Or

Action From Interface Module

<1A>

Not Used.

Not Used.

<1B>

Not Used.

Not Used.

<1C>

Request tLookup T

able data:

<1C><LL><0G><JJ>

Where 1) <LL> = message length = <02h>. 2) <OG> = Gun #. 3) <JJ> = Job #.

Response:

<1C><LL><OG><JJ> <F0><F0><O0><F1><F1><O!><F2><F2><O2><F3><F3><O3> <F4><F4><O4><F5><F5><O5><F6><F6><O6><F7><F7><O7> <F8><F8><O8><F9><O9>

Where: 1) <LL> = message length = <20h>. 2) <0G> = Gun #. 3) <JJ> = Job #. 4) <F0><F0> = Flow Rate for Entry #0. 5) <O0)> = Output for Entry #0. 6) <F1><F1> = Flow Rate for entry #1. 7) <O1> = Output for entry #1. 8) <F2><F2> = Flow Rate for entry #2. 9) <O2> = Output for entry #2. 10) <F3><F3> = Flow Rate for entry #3. 1

1) <O3> = Output for entry #3.

12) <F4><F4> = Flow Rate for entry #4. 13) <O4> = Output for entry #4. 14) <F5><F5> = Flow Rate for entry #5. 15) <O5> = Output for entry #5. 16) <F6><F6> = Flow Rate for entry #6. 17) <O6> = Output for entry #6. 18) <F7><F7> = Flow Rate for entry #7. 19) <O7> = Output for entry #7. 20) <F8><F8> = Flow Rate for entry #8. 21) <O8> = Output for entry #8. 22) <F9><F9> = Flow Rate for entry #9. 23) <O9> = Output for entry #9.

41

DynaFlow

Programer's Manual - Introduction

Ransburg

LN-9406-00.3

Advertising