Ransburg, Dynaflow, Programer's manual - introduction – Ransburg DynaFlow Programmers Manual User Manual
Page 37

Command T
ype
(hex)
Response Or
Action From User Interface
Response Or
Action From Interface Module
Where:
1) <LL> = message length = <01h>. 2) <0G> = Gun #.
Where: 1) <LL> = message length = <10h> 2) <0G> = Gun # 3) <FM><FM> = Filtered Master Channel Flow Rate 4) <FS><FS> = Filtered Slave Channel Flow Rate 5) <GS><GS> = Gun Status word (see below). 6) <TF> = Current trigger status, <00> = OFF
, and <FF> = ON
7)
<RR><RR>
=
Filtered
Curent
ratio
x
100.
8) <AS><AS> =
Analog set point in CC/min.
9) <V1> = Filtered Master Channel voltage output. 10) <V2> = Filtered Slave Channel voltage output. 1
1) <JQ> = Job Queue.
12) <AJ> =
Active Job #.
Gun Status word: Bit
0
=
Pot
Life
T
imer
Expired
Bit 1 =
Active
Bit 2 = Halted Bit 3 = Clean Mode Bit 4 = Enabled Bit 5 = Calibration Mode Bit 6 = Faulted Bit 7 = Ready Bit 8 = Busy Bit
9
=
Not
Configured
Bit 10 = Load Mode Bit
1
1
=
Configured
Without
Job
#.
Bit 12 =
Auto-tune Mode
Bit 13 =
Transparent Mode
Bit 14 =
Analog Hold
Bit 15 = Spare
<07>
Request for Gun Process data:
<07><LL>
Where: 1) <LL> = message length = <00>.
Response:
<07><LL><E1><E1><E2><E2><E3><E3><E4><E4><E5><E5> <E6><E6><E7><E7><E8><E8><E9><E9><E10><E10>
Where: 1) <LL> = message length = <14h>. 2) <E1><E1> = Latest Error Code 3) <E10><E10> = Oldest Error Code
33
DynaFlow
Programer's Manual - Introduction
Ransburg
LN-9406-00.3