background image

Command T

ype

(hex)

Response Or

Action From User Interface

Response Or

Action From Interface Module

Where:

1) <LL> = message length = <01h>. 2) <0G> = Gun #.

Where: 1) <LL> = message length = <10h> 2) <0G> = Gun # 3) <FM><FM> = Filtered Master Channel Flow Rate 4) <FS><FS> = Filtered Slave Channel Flow Rate 5) <GS><GS> = Gun Status word (see below). 6) <TF> = Current trigger status, <00> = OFF

, and <FF> = ON

7)

<RR><RR>

=

Filtered

Curent

ratio

x

100.

8) <AS><AS> =

Analog set point in CC/min.

9) <V1> = Filtered Master Channel voltage output. 10) <V2> = Filtered Slave Channel voltage output. 1

1) <JQ> = Job Queue.

12) <AJ> =

Active Job #.

Gun Status word: Bit

0

=

Pot

Life

T

imer

Expired

Bit 1 =

Active

Bit 2 = Halted Bit 3 = Clean Mode Bit 4 = Enabled Bit 5 = Calibration Mode Bit 6 = Faulted Bit 7 = Ready Bit 8 = Busy Bit

9

=

Not

Configured

Bit 10 = Load Mode Bit

1

1

=

Configured

Without

Job

#.

Bit 12 =

Auto-tune Mode

Bit 13 =

Transparent Mode

Bit 14 =

Analog Hold

Bit 15 = Spare

<07>

Request for Gun Process data:

<07><LL>

Where: 1) <LL> = message length = <00>.

Response:

<07><LL><E1><E1><E2><E2><E3><E3><E4><E4><E5><E5> <E6><E6><E7><E7><E8><E8><E9><E9><E10><E10>

Where: 1) <LL> = message length = <14h>. 2) <E1><E1> = Latest Error Code 3) <E10><E10> = Oldest Error Code