RIO Hardware Settings

The DynaFlow Interface Module (77377-02) has

several DIP switch settings that establish the op-

erating characteristics of the RIO port.

RIO Rack Address

The RIO Rack Address is used to indicate to which

RIO rack the Interface Module is assigned. RIO

Rack Addresses are specified in octal format.

There are 64 decimal possible Rack Addresses,

which are assigned 00 through 77 octal.

There are five (5) words of discrete inputs and

five (5) words of discrete output possible for each

DynaFlow Interface Module. Each DynaFlow

Interface Module supports up to four (4) Chan-

nel Cards and each Channel Card has two (2)

Channels for a total of eight (8) Channels. The

PLC discrete I/O RIO output bits are logical OR'd

with the discrete I/O hard-wired signals so that

either hard-wired signals or PLC control signals

may control the system. Likewise, the DynaFlow

hard-wired outputs are sent to the PLC via the

discrete I/O RIO inputs.

The DynaFlow system uses two-slot addressing

and appears to a PLC as a collection of 8-bit

modules of I/O. In other words, each module has

8 inputs and 8 outputs. The Interface Module

appears as a single 8-bit I/O module in slot 1,

or the odd slot of a pair of slots. Therefore, the

Interface Module, which reports the System I/O

signals, uses the high byte of word 0.

Each DynaFlow Channel Card appears as two

8-bit I/O modules. The first channel appears in

the low byte and the second channel appears in

the high byte of each successive word in the RIO

discrete I/O space.

With two-slot addressing, each rack contains 8

I/O groups (0-7). The following table describes

how DynaFlow is assigned within a rack.

I/O

Group

0

1

2

3

4

5

6

7

Ø

Interface Module

Channel Module #1

Channel Module #2

Channel Module #3

Channel Module #4

Interface Module

Channel Module #1

Channel Module #2

Channel Module #3

Channel Module #4

1

2

Interface Module

Channel Module #1

Channel Module #2

Channel Module #3

3

Interface Module

Channel Module #1

STARTING QUARTER

44

DynaFlow

Programer's Manual - Installation