Command T
ype (hex)
Response Or
Action From User Interface
Response Or
Action From Interface Module
Bit 13 = Bit 14 = Bit 15=
<16>
Request to Force
Analog Output:
<16><LL><OC><A1><A2>
Where: 1) <LL> = message length = <03h>. 2) <0C> = Channel #. 3) <A1> = D/A
Output #1
4) <A2> = D/A
Output #2.
Response:
ACK <FF>
Note:
The
Gun
that
the
Channel
is
co
nfigured
to
must
be
in Ready mode and not
Active.
The forced analog output
value must be returned to <00> before requesting that the (Gun) become Active.
<17>
Request for Current
Analog V
alues:
<17><LL><0C>
Where: 1) <LL> = message length = <01h>. 2) <0C> = Channel #.
Response:
<17><LL><0C><AI><AI><SI><SI><T
A><SA>
Where: 1) <LL> = message length = <07h>. 2) <0C> = Channel #. 3) <AI><AI> =
Analog Input.
4) <SI><SI> = Spare
Analog Input.
5) <T
A> =
Transducer
Analog Output
6) <SA> = Spare
Analog Output
<18>
Request to Rest Grand T
otal V
olume for a Channel for a Job:
<18><LL><0C><JJ>
Where: 1) <LL> = message length = <02h>. 2) <0C> = Channel #. 3) <JJ> = Job #.
Response:
ACK <FF>
<19>
Request to Reset Grand T
otal V
olume for a Channel for
All Jobs: <18><LL><0C> Where: 1) <LL> = message length = <01h>. 2) <0C> = Channel #.
Response:
ACK <FF>
Note: W
ait 200 milliseconds before issuing another command to
allow the Interface Module time to complete the transfer
.
40