Command T

ype (hex)

Response Or

Action From User Interface

Response Or

Action From Interface Module

Bit 13 = Bit 14 = Bit 15=

<16>

Request to Force

Analog Output:

<16><LL><OC><A1><A2>

Where: 1) <LL> = message length = <03h>. 2) <0C> = Channel #. 3) <A1> = D/A

Output #1

4) <A2> = D/A

Output #2.

Response:

ACK <FF>

Note:

The

Gun

that

the

Channel

is

co

nfigured

to

must

be

in Ready mode and not

Active.

The forced analog output

value must be returned to <00> before requesting that the (Gun) become Active.

<17>

Request for Current

Analog V

alues:

<17><LL><0C>

Where: 1) <LL> = message length = <01h>. 2) <0C> = Channel #.

Response:

<17><LL><0C><AI><AI><SI><SI><T

A><SA>

Where: 1) <LL> = message length = <07h>. 2) <0C> = Channel #. 3) <AI><AI> =

Analog Input.

4) <SI><SI> = Spare

Analog Input.

5) <T

A> =

Transducer

Analog Output

6) <SA> = Spare

Analog Output

<18>

Request to Rest Grand T

otal V

olume for a Channel for a Job:

<18><LL><0C><JJ>

Where: 1) <LL> = message length = <02h>. 2) <0C> = Channel #. 3) <JJ> = Job #.

Response:

ACK <FF>

<19>

Request to Reset Grand T

otal V

olume for a Channel for

All Jobs: <18><LL><0C> Where: 1) <LL> = message length = <01h>. 2) <0C> = Channel #.

Response:

ACK <FF>

Note: W

ait 200 milliseconds before issuing another command to

allow the Interface Module time to complete the transfer

.