Ransburg, Dynaflow, Programer's manual - introduction – Ransburg DynaFlow Programmers Manual User Manual

Page 43

Advertising
background image

Command T

ype (hex)

Response Or

Action From User Interface

Response Or

Action From Interface Module

<13>

Request to Stop Calibration for a Channel: <13><LL><0C> Where: 1) <LL> = message length = <01h>. 2) <0C> = Channel #.

Response: <13><LL><0C><CN><CN><CP><CP><CT><CT> Where: 1) <LL> = message length = <07h>. 2) <0C> = Channel #. 3) <CN><CH> = Calibration Control word. 4) <CP><CP> = # pulses received during calibration. 5) <CT><CT> = calibration time.

<14>

Request to Copy

Attached Pulses Per Liter to a Range of

Jobs: <14><LL><PL><PL><PL><PL><JW><CX><JY> Where: 1) <LL> = message length = <07h>, 2) <PL><PL><PL><PL> = pulses per liter

.

3) <JW> = starting target Job #. 4) <CX> = starting target Channel #. 5) <JY> = ending target Job #.

Response:

ACK <FF>

Note: W

ait 200 milliseconds before issuing another command to

allow the Interface Module time to complete the transfer

.

<15>

Send Current Status of Gun Keys: <15><LL><0G><OS><OS> Where: 1) <LL> = message length = <03h>. 2) <0G> = Gun #. 3) <OS><OS> = Operator Status word (see below). Operator Status word: Bit 0 =

Trigger

Bit 1 =

Active mode

Bit 2 = Halt Bit 3 = Clean mode Bit 4 = Bit 5 = Calibration mode Bit 6 = Reset Gun Fault Bit 7 = Bit 8 = Bit 9 = Bit 10 = Load Mode Bit 1

1 =

Bit 12 =

Auto-tune mode

Response:

ACK <FF>