Command T

ype (hex)

Response Or

Action From User Interface

Response Or

Action From Interface Module

Gun Output & Forced Gun Output bytes: Bit 0 = Ready bit 1 =

Active

Bit 2 = Fault Bit 3 = Pot Life Fault Bit 4 = Clean Bit 5 = Load Bit 6 = Calibrate Bit 7 = MVR Enable

RIO System Input byte: Bit 0 = System Halt Bit 1 = Fault Reset Bit 2 = Global Gun Enable

<04>

Request for System Configuration data:

<04><LL>

Where: 1) <LL> = message length = <00>.

Response:

<04><LL><HV><HV><IV><IV><S1><S2><BO><PT> <HC><HC><PW><PW><PW><PW><SI><SI><SO><SO> <C1><C1><C2><C2><C3><C3><C4><C4><12><34><56><78>

Where: 1) <LL> = message length = <1Eh>. 2)

<HV><HV>

=

Host

V

ergion

(hex

value).

3)

<IV><IV>

=

Interface

V

ersion

(hex

value).

4) <S1><S2> = Interface Module DIP

SW1 and SW2.

5) <BO> = Blow Of

f T

ime in seconds.

6) <PT> = Password

Timer

.

7) <HC><HC> = Horn Code (see below). 8) <PW><PW><PW><PW> = Password. 9) <SI><SI> = System Input word 10) <SO><SO> = System Output word. 1

1)

<C1><C1>

=

Channel

Card

#1

V

ersion

(hex

value).

12)

<C2><C2>

=

Channel

Card

#2

V

ersion

(hex

value).

13)

<C3><C3>

=

Channel

Card

#3

V

ersion

(hex

value).

14)

<C4><C4>

=

Channel

Card

#4

V

ersion

(hex

value).

15)

<12>

=

Channel

Card

#1

DIP

Switch

(hex

value).

16)

<34>

=

Channel

Card

#2.

DIP

Switch

(hex

value).

17)

<56>

=

Channel

Card

#3.

DIP

Switch

(hex

value).

18)

<78>

=

Channel

Card

#4.

DIP

Switch

(hex

value).

Horn Code: Bit 0 = Fault Bit

1

=

Pot

Life

time

exceeded

Bit

2

=

External

System input word: Bit 0 = Job Select BCD 001.