background image

Command T

ype (hex)

Response Or

Action From User Interface

Response Or

Action From Interface Module

<0A>

Request to Reset Daily T

otals for a Channel for

All Jobs: <1A><LL><0C> Where: 1) <LL> = message length = <01h>. 2) <0C> = Channel #.

Response:

ACK <FF>

<0B>

Request to Reset

YTD T

otals for a Channel for

All Jobs:

<0B><LL><0C> Where: 1) <LL> = message length = <01h> 2) <0C> = Channel #.

Response:

ACK <FF>

<0C>

Request to Reset Calibration T

otals for a Channel for

All

Jobs: <0C><LL><0C> Where: 1) <LL> = message length = <01h>. 2) <0C> = Channel #.

Response:

ACK <FF>

<0D>

Request to Reset Clean T

otals for a Channel for

All Jobs:

<0D><LL><0C> Where: 1) <LL> = message length = <01h>, 2) <0C> = Channel #.

Response:

ACK <FF>

<0E>

Request to Reset Daily T

otals for a Channel for a Job:

<0E><LL><0C><JJ> Where: 1) <LL> = message length = <02h>. 2) <0C> = Channel #. 3) <JJ> = Job #.

Response:

ACK <FF>

<0F>

Request to Reset

YTD totals for a Channel for a Job:

<0F><LL><0C><JJ> Where: 1) <LL> = message length = <02h>. 2) <OC> = Channel # 3) <JJ> = Job #.

Response:

ACK <FF>

36