Ransburg, Sio baud rate, Sio cable connection – Ransburg DynaFlow Programmers Manual User Manual

Page 52: Sio driver levels, Sio hardware settings, Sio port configuration, Dynaflow, Programer's manual - installation

Advertising
background image

Since there is no hardware or software flow control,

it is up to the receiving device at both ends of the

connection to keep up with the sending device.

It is recommended that the receiver be interrupt

driven. Polling may be used to control the trans-

mitter. The Interface Module utilizes interrupts to

control both transmit and receive on the SIO port.

SIO Baud Rate

The SIO Baud Rate is specified in SW2, positions

5 and 6 as shown below:

SIO Cable Connection

The SIO connection is made using two pair shield-

ed cable. The connections are made at the rear

of the DynaFlow backplane on connector J8.

SIO Driver Levels

The SIO port supports full duplex RS-232C or

RS-422 driver levels. The following table shows

the maximum cable lengths recommended for

each level. Whenever possible, RS-422 should

be utilized. The 19.2 Kbaud is the near the the-

oretical maximum baud rate for RS-232C and is

more susceptible to electrical noise.

Jumper E5 on the Interface Module selects either

RS-232C or RS-422 mode. Jumper E5 controls

whether 120 ohm terminating resistor is installed

for RS-422 or RS-485 operation. (Factory default

settings in bold)

SW2-5

SW2-6

OFF

OFF

ON

ON

OFF

ON

OFF

ON

19.2 Kbaud

4.8 Kbaud

9.6 Kbaud

38.4 Kbaud

SIO Baud Rate

Driver

Level

Jumper E5

RS-232C

RS-422

2-3

1-2

X

Install

Jumper E10 -

120 ohm Terminating

Resistor

Connection

J8-1

J8-2

J8-3

J8-4

J8-5

J8-6

J8-7

J8-8

RS-422 Receive (+)

RS-422 Receive (-)

RS-422 Transmit (+)

RS-422 Transmit (-)

RS-422 & RS-485 Ground

RS-232C Receive

RS-232C Transmit

RS-232C Ground

DynaFlow

Backplane

Driver

Level

Max. Shielded

Cable Length

RS-232C

RS-422

50 Ft.

4,000 Ft.

25 Ft.

4,000 Ft.

Max. Unshielded

Cable Length

SIO Hardware Settings

The DynaFlow Interface Module (77377-02) has

several DIP switch and jumper settings that estab-

lish the operating characteristics of the SIO port.

SIO Port Configuration

Data Bits Start Bits

8

1

Parity

None

None

Flow

Control

Stop Bits

1

48

DynaFlow

Programer's Manual - Installation