Ransburg, Dynaflow, Programer's manual - introduction – Ransburg DynaFlow Programmers Manual User Manual
Page 41

Command T
ype (hex)
Response Or
Action From User Interface
Response Or
Action From Interface Module
<10>
Request to Reset
All Calibration T
otals for a Channel for
a Job:
<10><LL><0C><JJ>
Where: 1) <LL> = message length = <02h>. 2) <0C> = Channel #. 3) <JJ> = Job #
Response:
ACK <FF>
<1
1>
Request to Copy
All Job Parameters from Gun/Job to a
Range of Gun W/Job X to Gun
Y/Job Z:
<1
1><LL><OG><JJ><OW><JX><OY><JZ>
Where: 1) <LL> = message length = <06h>. 2) <0G> = Source Gun #. 3) <JJ> = Source Job #. 4) <OW> = Starting
Target Gun #.
5) <JX> = Starting
Target Job #.
6) <OY> = Ending
Target Gun #.
7) <JZ> = Ending
Target Job #.
See
Types <02> and <09> to see what information is transferred.
Response:
ACK <FF>
Note: W
ait 200 milliseconds before issuing another command
to allow the Interface Module time to complete the transfer
.
<12>
Request to Copy a Single Job Parameter from Gun/Job to a Range of Gun W/Job X to Gun
Y/Job Z:
<12><LL><PP><OG><JJ><OW><JX><OY><JZ>
Where: 1) <LL> = message length = <07h>. 2) <PP> = Parameter # (see below). 3) <OG> = Source Gun #. 4) <JJ> = Source Job #. 5) <OW> = Starting
Target Gun #.
6) <JX> = Starting
Target Job #.
7) <OY> = Ending
Target Gun #.
8) <JZ> = Ending
Target Job #.
Response:
ACK <FF>
Note: W
ait 200 milliseconds before issuing another command
to allow the Interface Module time to complete the transfer
.
37
DynaFlow
Programer's Manual - Introduction
Ransburg
LN-9406-00.3