Vector R Series Cascade Applicators - Installation

Ransburg

18

79500 R90 SOLVENTBORNE

79501 R70 SOLVENTBORNE

INSTALLATION

†

The control unit

MUST be located out-

side of the spray area.

†

The User

MUST read and be familiar

with the "Safety" section of thismanual.

†

This manual

MUST be read and thor-

oughly understood by

ALL personnel who

operate, clean, or maintain this equipment!

Special care should be taken to ensure that

the warnings and requirements for operating

and servicing safety are followed. The user

should be awre of and adhere to

ALL local

building and fire codes and ordinances as

well as NFPA, OSHA, and all related coun-

try safety codes prior to installing, operating,

and/or servicing this eqiupment.

†

The fluid lines and fluid sources

MUST

be isolated from ground for waterbase ap-

plications.

†

Personnel

MUST be GROUNDED to

prevent a shock or spark during electrostatic

operation.

†

Install and route the hoses and cable so

they are

NOT exposed to temperatures in

excess of 120°

F and so that all hose and

cable bends are

NO LESS than a 6 inch

(15cm) radius. Failure to comply with these

parameters cold cause equipment malfunc-

tion that might create

HAZARDOUS CON-

DITIONS!

†

Install only one spray applicator per iso-

lated waterborne fluid supply system.

W A R N I N G

!

†

NEVER wrap the applicator, associated

valves and tubing, and supporting hardware

in plastic to keep it clean. A surface charge

may build up on the plastic surface and dis-

charge to the nearest grounded object. Effi-

ciency of the applicator will also be reduced

and damage or failure of the applicator

components may occur.

WRAPPING THE

APPLICATOR IN PLASTIC WILL VOID

WARRANTY. Only approved applicator

covers should be used.

W A R N I N G

!

TYPICAL

SOLVENTBORNE

INSTALLATION

(See "Figure 3 - Typical Solventborne

Installation Features")

Location of Control Unit

Install the low voltage control unit in an area

out-

side the hazardous location in accordance with

federal, state, and local codes. The area should

protect the control unit from the possibility of en-

vironmental intrusion (such as dust or moisture),

have ambient temperatures that do not exceed

120°F, and be as close to the applicator as pos-

sible to minimize the length of low voltage cable.

INSTALLATION

AH-06-01.13