Ransburg, Waterborne hose fitting installation – Ransburg Vector R Series Cascade 79523 R90 Waterborne User Manual

Page 65

Advertising
background image

Vector R Series Cascade Applicators - Waterborne

Ransburg

61

WATERBORNE

ISOLATION SYSTEM

INSTALLATION

GUIDELINES

Using waterborne coating with electrostatic equip-

ment requires that the fluid source be isolated

from ground. Precautions should be taken to

ensure operator safety and system efficiency. The

following guidelines should be followed:

• The fluid lines and source MUST be isolated

from ground. An isolating Paint Stand or

similar isolating (non-porous) material MUST

be used.

†

Never use wood products, wooden box-

es, pallets, or boards as an isolator. Wood

contains moisture and is a poor insulator.

Electrical current passing through these ma-

terials can ignite them, causing a hazardous

condition.

C A U T I O N

!

• Isolation stands MUST be at least 18-inches

from grounded booth walls, chain link fences,

or other grounded objects.

• Air hoses to the pressure pot or pump on the

insulating stand should be non-conductive

plastic. Many rubber hoses will have static

grounding circuits or carbon content and are

NOT suitable for this application.

WATERBORNE HOSE

FITTING INSTALLATION

For 79523 R90 Cascade - Waterborne: Rans-

burg supplies the waterborne fluid hose factory

pre-assembled to the applicator unit. Standard

hose lengths are 10m, 15m, and 25m. To modify

the hose length, use the following procedures. All

adjustments must be made at the supply end of

the system.

1. Remove the male connector and swivel fitting

from the end of the fluid hose by turning the nut

of the male connector counter-clockwise while

holding its main body.

2. Remove the male connector nut from the fluid

hose.

3. Determine the hose length that is needed and

cut the hose off squarely.

All charged (isolated) systems MUST be inside

a fence or cage to prevent contact by personnel.

An interlock system MUST be provided that

interrupts high voltage flow to the applicator if

the gate is opened.

Air regulators for pots or pumps should be

mounted remotely outside the fence or cage

area to facilitate changes in pressure without

shutting the system down.

Grounding hooks at the cage MUST be used to

ground the system when personnel are working

close by.

Fluid lines to the applicator MUST be protected

from scraping and abrasion on the floor or

sharp metal edges that could lead to voltage pin

holing and loss of kV on the charged system.

Cleanliness and maintenance are extremely

critical.

Refer to "Installation - 79500 R90 Solventborne,

79501 R70 Solventborne Installation" in the

"Installation" section of this manual.

†

Typical installations to spray non-flam-

mable conductive materials (waterborne ma-

terials) must not be used to handle flamma-

ble materials (solvent based materials).

W A R N I N G

!

AH-06-01.13

Advertising