Vector R Series Cascade Applicators - Operation

Ransburg

27

When a kV setpoint button is pressed, the light

above the button will light and the kV display will

show the present voltage for that setpoint. This

indicates the unit is set to spray at that setpoint.

To adjust the kV for the present setpoint, press

the + or - setpoint adjust buttons.

When the + or - setpoint adjust buttons are held

in longer than 1 second, the kV display will be-

gin incrementing or decrementing in units of 5

instead of 1.

†

DO NOT turn the applicator off using the

applicator button in place of interlocking with

a solvent supply for flushing. The applicator

must be interlocked with solvent supply such

that when the solvent is on to flush the appli-

cator, there is no kV at the applicator.

W A R N I N G

!

Figure 6: Changing Setpoint

Changing the Setpoint at the

Applicator

To change the setpoint at the applicator, the ap-

plicator must NOT be triggered. By pushing the

kV button on the rear cover of the applicator, the

setpoint will change. If there are 2 green lights lit,

setpoint 1 is active. If 2 green lights and 2 yellow

lights are lit, setpoint 2 is active. If all lights are lit

(2 green lights, 2 yellow lights, and 2 red lights)

setpoint 3 is active.

kV to the applicator can be turned off by pressing

the applicator kV button in for 2-3 seconds. This

can be done whether the applicator is triggered

or not and is useful if the kV needs to be turned

off for spraying into recessed areas. When the

kV is disabled in this manner, the kV meter will

read zero, OFF will be displayed in the microamp

meter and all kV setpoint indicator lights will be

disabled. Pressing the kV button in for another

2-3 seconds turns the kV to the applicator back on.

Figure 7: View of Rear Cover

LOCKOUTS

There are lockouts that may be done at the PC

board (see Figure 8). These lockouts may be used

individually or in combination as required. If the

jumpers are disconnected, the original functions

are re-enabled. After changing any jumpers, the

AC power must be cycled for the new setting to

take affect.

Figure 8: Lockout Jumper Location