Maintenance, Ransburg – Ransburg Vector R Series Cascade 79523 R90 Waterborne User Manual

Page 35

Advertising
background image

Vector R Series Cascade Applicators - Maintenance

Ransburg

31

†

The user

MUST read and be familiar

with the safety instructions

in this manual.

†

If compressed air is used in cleaning,

REMEMBER that high pressure air can be

dangerous and should

NEVER be used

against the body

. It can blind, deafen, and

may even penetrate the skin. If used for

cleaning equipment, the user should wear

safety glasses.

†

ALWAYS turn the control unit's pow-

er off prior to cleaning and servicing the

equipment.

†

Be

SURE the power is OFF and the

system is grounded before using solvent to

clean

ANY equipment.

†

DO NOT operate a faulty applicator!

†

When using cleaning solvent, standard

health and safety precautions should apply.

†

Any solvent used to clean the fluid pas-

sages must be discharged into a ground-

ed container. Use of ungrounded or plastic

containers may cause fire or explosion.

†

Cleaning of the exterior surface of the

applicator should be done with non-polar

solvents. If cleaning requires the use of po-

lar solvents, the applicator should be wiped

down with non-polar solvent prior to going

back into use. Using polar solvents will

leave a semi-conductive film on the surface

of the applicator that will effect efficiency

of the applicator and cause damage to the

components.

W A R N I N G

!

SUITABLE SOLVENTS

FOR CLEANING VECTOR

R90/70 APPLICATORS

When cleaning the applicator, a suitable solvent

for cleaning depends on the part(s) of the appli-

cator to be cleaned and the material that needs

to be removed. Ransburg recommends that all

exterior cleaning be done with non-polar solvents

to prevent a conductive residue on critical com-

ponents. We also understand that some of these

solvents do not always meet the cleaning needs

of some materials. If conductive polar solvents

are used to clean the applicator components, all

residue must be removed using a non-conductive

non-polar solvent (i.e. high flash Naphtha). If there

are any questions as to what solvents are best for

cleaning , contact your local Ransburg distributor

and/or your paint supplier.

The Vector applicator, air hoses, fluid hose, and

high voltage cable assemblies should not be

submerged or soaked in solvent. However, the

outer surfaces of these items can be wiped with

a suitable cleaning solvent. The items that can-

not be soaked are noted throughout this manual.

All electrical components

cannot be cleaned or

soaked in any solvents.

MAINTENANCE

AH-06-01.13

Advertising