Vector R Series Cascade Applicators - Maintenance

Ransburg

46

Figure 34: Fluid Bracket Removal

Figure 35: Trigger Shelf Removal

Figure 36: Trigger Stop Removal

6. Remove the air inlet fitting and the fluid bracket

from the base of the applicator.

7. Remove the trigger shelf by removing the set

screw with a 3/32" Allen wrench. Push down on

the shelf to remove.

8. Remove the trigger stop by turning the knob

of the stop counter-clockwise until the thread of

the stop is completely disengaged.

1 - Fluid Bracket

2 - Air Inlet Solvent Proof O-Ring

3 - Air Inlet Fitting

1 - Finger Shelf Set Screw

2 - Finger Shelf (pushed down)

1 - Trigger Stop Assembly

Reassembly

(Refer to Figures 31, 32, 33, 34, 35, 36,

37, and 38)

1. Screw the trigger stop into the handle in a

clockwise direction.

2. Push the finger shelf up on the dovetail pad

on the handle to the desired height, insert the set

screw and tighten with a 3/32" Allen wrench.

3. Insert the fluid bracket over the air fitting, then

install the o-ring over the air fitting. Tighten the

air fitting in a clockwise direction.