Ransburg, Vector r series cascade applicators - maintenance – Ransburg Vector R Series Cascade 79523 R90 Waterborne User Manual

Page 47

Advertising
background image

Vector R Series Cascade Applicators - Maintenance

Ransburg

43

†

DO NOT overtighten the hexagon adjust-

ment nuts or damage may occur to the plas-

tic threads or the needle shaft may break.

Finger tight is typically sufficient. (Maximum

torque of 18-24 in•oz).

C A U T I O N

!

Figure 29: Trigger Adjustment Nut Dimensions

Figure 27: Spring Washer Assembly Sequence

†

All six (6) spring washers

MUST be re-

placed alternately as shown in Figure 33, or

the applicator will malfunction.

W A R N I N G

!

12. Place the packing nut (large bore first) on the

rear needle shaft section.

13. Screw the trigger adjustment nut onto the rear

needle shaft section with the hexagon rearward

and the spring retainer with the hexagon forward.

Do not lock the hexagon nuts in place.

14. Install the needle shaft sub-assembly into the

packing chamber from the rear of the barrel with

the needle/electrode forward.

15. Push the needle shaft sub-assembly forward

until the packing nut will engage its mating thread

in the barrel and screw it into place by hand, ap-

proximately 3 turns.

16. Pull the needle shaft rearward as far as it

will go.

17. Install the fluid nozzle, air cap, and retaining

nut (refer to "Air Cap" and "Fluid Nozzle" in the

"Maintenance" section).

18. Tighten the packing nut using the spanner

tool on the special multi-purpose wrench until a

firm resistance is felt on the needle shaft while

reciprocating it by hand.

Figure 28: Needle Shaft Assembly Into Barrel

19. Push the needle shaft forward until the needle/

electrode seats into the fluid nozzle.

20. Adjust the trigger adjustment nut as far forward

on the needle shaft as possible.

21. Adjust the needle shaft spring retainer until

the rear of the hexagon is 11/16-inch from the

rear surface of the barrel packing chamber (refer

to Figure 29).

22. Hold the spring retainer in place and screw the

front trigger adjustment nut rearward until contact

is made. Use two 3/8" open-end wrenches to

tighten and lock the adjustment nuts in place on

the needle shaft.

AH-06-01.13

Advertising