FLUSHING

PROCEDURES

1. Turn OFF the control unit power.

†

Whenever solvent is flushed through the

applicator the control unit power must be off.

W A R N I N G

!

2. Turn the paint supply OFF.

3. Turn the atomizing air supply OFF.

4. Tilt the applicator down and trigger until it is

clear of paint.

5. Connect the solvent supply.

6. Run solvent through the system until it runs

clear.

†

DO NOT allow the fluid lines to stand

empty without flushing first! This will cause

dried paint flaking and clogging of the fluid

lines, applicator passages, and/or nozzles.

C A U T I O N

!

APPLICATOR REPAIR

All repairs should be made on a clean, flat sur-

face. If a vise is used to hold parts during service

or repair, DO NOT clamp onto plastic parts and

always pad the vise jaws!

The following parts should be thoroughly packed

with dielectric grease (LSCH0009-00) leaving NO

air space or voids when assembling:
• All O-Rings (PTFE o-rings do not need

lubrication)

• Needle Shaft Assembly

• Packing Tube

• Cartridge Assembly, Non-Adjustable

• Air Valve Rod Assembly

Apply sealant (7969-10) to the external threads

of the following parts when assembling:
• Nut Air Valve Retaining (78635-00)

• Cap, Air Valve (79317-00)

Equipment Required

• Special Multi-Purpose Wrench (19749-00)

• 3/32" Allen Wrench for Set Screws

• Screwdriver (blade)

• Dielectric Grease (LSCH0009-00)

• Sealant, Medium Strength (7969-10)

• Plastic or Wood Dowel Rod, 5/16" Diameter

†

Any solvent used to clean the fluid pas-

sages must be discharged into a grounded

container. Use of ungrounded or plastic

containers may cause fire or explosion.

W A R N I N G

!

7. Disconnect the solvent supply.

8. Trigger the applicator until it is clear of sol-

vent. After the preceding steps are complete, the

applicator is ready for color change, storage, or

maintenance.

AH-06-01.13