Vector R Series Cascade Applicators - Installation

Ransburg

21

FILTERS

1. Install an air filter assembly on the air inlet of

the control unit. The filter should be 5 micron with

a maximum working pressure of at least 100 psig

(6.9 bar). Screw the fitting into the filter inlet. The

filter MUST be installed with the arrow pointing in

the direction of flow. (Refer to the appropriate Filter

Assembly manual for "Installation Instructions".)

When the applicator is triggered, the resulting

air flow closes the contacts of the air flow switch,

thereby activating high voltage at the applicator.

2. Ransburg recommends that a fluid filter be

installed at the output of the fluid supply (pressure

pot, pump, circulating system, etc.). It is the end

user's responsibility to install the proper filter that

meets their system's requirements.

LOW VOLTAGE CABLE

Connect the low voltage cable from the control

unit to the applicator using a wrench to tighten.

Figure 10: Daisy Chained Cable

†

DO NOT over-tighten the low voltage

connection at the applicator. The plastic

parts could be damaged.

C A U T I O N

!

With the Vector design, multiple cables may be

connected together to create the length required,

up to a maximum of 30m (100 ft.). To connect

the cables, insert the male end of one cable into

the female end of the other. Tighten both cable

connectors against each other using two (2) 16mm

(5/8") open-end wrenches.

†

The electrical discharge that is avail-

able from the charging electrode must not

exceed 0.24 mJ of energy. To achieve this

limit, any flow of energy from the paint sup-

ply through the paint line to the applicator

electrode must be prevented by grounding

the paint line at the applicator handle.

Verify that the applicator handle is actually

grounded before operating it! This is done

with a fully connected and operational sys-

tem, by placing one lead of an ohmmeter

to the handle and the other to the building

electrical ground (cold water pipe, building

structure, steel, etc.). This reading should be

essentially zero.

If a greater reading is obtained, check that

the control unit is grounded. (See the control

unit manual for "Grounding Procedure.")

W A R N I N G

!

†

An air filter

MUST be installed to permit

proper functioning of the air flow switch in-

side the control unit. This unit must filter par-

ticles 5 microns and larger.