Vector R Series Cascade Applicators - Maintenance

Ransburg

45

Figure 33: Hook and Plug Assembly Removal

5. Remove the hook and hook gasket. Loosen

the plug assembly setscrew and pull the plug

assembly straight out of the applicator.

HANDLE / PLUG

ASSEMBLY

Removal

1. The following procedures must be performed

prior to removing the handle:

• Barrel removal

• Low Voltage Cable removal

• Fluid/Air Hose removal

2. Remove the gasket from the handle; if it was

not removed with the barrel.

3. Remove the fan air adjustment valve, pull the

rear cover straight off.

Figure 31: Air Valve and Rear Cover Removal

4. Remove the air valve retaining cap and o-ring.

Remove the air valve return spring. From the front

of the applicator, push the air valve out the rear

of the applicator. Remove the air valve retaining

nut and seal from the base of the applicator.

Figure 32: Air Valve Removal

1 - Barrel Gasket

2 - Fan Air Adjustment Valve

3 - Rear Cover

1 - Air Valve Retaining Nut

2 - Seal (opening toward applicator rear)

3 - Air Valve

4 - Air Valve Return Spring

5 - Solvent Proof O-Ring

6 - Air Valve Retaining Cap

1 - Hook

2 - Hook Gasket

3 - Plug Assembly Set Screw (loosen)

4 - Plug Assembly (pull straight out)

1

2

3

1

2

3

4

6

5

1

2

3

4

AH-06-01.13