Vector R Series Cascade Applicators - Maintenance

Ransburg

39

NEEDLE / ELECTRODE

RESISTANCE TESTING

The electrical resistance of the needle/electrode

should be tested periodically (typically on a weekly

basis) or any time it is removed from the applicator.

To Test

1. Install the needle/electrode onto the front end

of an available needle shaft. Be sure that the

needle/electrode is completely seated for proper

contact between the metal shaft and the threaded

insert of the needle/electrode.

2. Using a VOM meter that will read 15 megohms

accurately, connect the first meter lead to the metal

needle shaft and the second lead to the needle/

electrode wire. The needle/electrode resistance

should be 14.5 to 19 megohms (nominal 15 meg-

ohms at 9 volts or 12 to 17 megohms at 1000

volts). Needle/electrodes outside these ranges

must be replaced.

BARREL ASSEMBLY

Removal

1. While holding the barrel with one hand, loosen

the air cap retaining nut using the other hand.

2. Unscrew the retaining nut completely and

remove the air cap.

3. Using a flat head screwdriver, loosen the two

(2) shoulder screws that retain the trigger to the

applicator handle.

Figure 22: Barrel Assembly Removal

4. Remove trigger from the applicator handle.

5. Using an adjustable wrench, unscrew the fluid

tube connector from the barrel and slide it down

the fluid tube. The fluid tube must be removed

prior to removing the barrel to prevent damage

to the cascade.

6. Use the special multi-purpose wrench to loosen

the retaining nut that secures the barrel to the

applicator handle. After unscrewing the nut, slide

it forward onto the barrel.

7. Hold the applicator handle and fluid tube so the

barrel points downward. With the other hand, pull

the barrel forward to separate it from the handle.

Once the barrel has cleared the handle, remove

the spring from the spring retainer and set it aside.

C C W

Figure 21: Testing Resistive Electrode

AH-06-01.13