INSTALLATION

• Ensure that all elements of the coating system

are correctly grounded, connected, and located.

• Position all non-approved electrical apparatus

(including, but not limited to, high voltage power

supplies, fluid pumps, and air compressors)

outside of the hazardous location. See the

appropriate country or local codes.

• Provide appropriate fire extinguishing equipment.

• Provide conductive flooring in all spray areas.

TYPICAL AA90 CASCADE

APPLICATOR

INSTALLATION

Connect the low voltage cable to the control unit low

voltage socket. Gently hand tighten the cable retaining

nut. Connect the other end of the low voltage cable

to the applicator, using a wrench to tighten. Slide the

cable boot over the nut.

SAFE INSTALLATION

• Ground the spray booth, the paint supply, and

the conveyor or work support.

• Ground all solvent and waste safety containers.

• Ground all work holders and hooks and keep

them free of paint.

• Ground the target object to a structural ground

and not back to the applicator system. Ensure

that all target objects have a resistance to ground

of one megohm or LESS.

This information is intended ONLY to indicate

general installation guidelines of this product and

its working relationship to other Ransburg system

components. Each installation is unique and

should be directed by an Ransburg representative.

The control unit may be connected through conduit

with an explosion-proof switch on or near the spray

booth where it will be convenient to the operator,

or may be connected with a power cord depending

upon application requirement.

†

Install and route the hoses and cable so

they are

NOT exposed to temperatures in

excess of 120

°

F and so that all hose bends

are

NOT LESS than a 6-inch (15 cm) radi-

us. Failure to comply with these guidelines

could cause equipment malfunctions that

might create

HAZARDOUS CONDITIONS!

W A R N I N G

!

>

DO NOT overtighten the low voltage

cable connection to the applicator. Dam-

age to plastic parts may occur.

C A U T I O N

!

†

Target grounding wire must not be con-

nected directly to the ground lug of the 9060.

A seperate ground line must be used for

each connection.

C A U T I O N

!