Vector AA90 Applicators - Installation

LOW VOLTAGE CABLE

Connect the low voltage cable from the control

unit to the applicator using a wrench to tighten.

Figure 11: Daisy Chained Cable

>

DO NOT overtighten the low voltage

connection at the applicator. The plastic

parts could be damaged.

C A U T I O N

!

With the Vector design, multiple cables may be

connected together to create the length required,

up to a maximum of 30m (100 ft.). To connect

the cables, insert the male end of one cable into

the female end of the other. Tighten both cable

connectors against each other using two (2) 16mm

(5/8") open-end wrenches.

†

The control unit power supply MUST be

located at least 3 feet outside of the spray

area. Install units in accordance with the

code requirements. (See local and national

codes.)

W A R N I N G

!

†

The electrical discharge that is available

from the charging electrode must not exceed

0.25 mJ of energy. To achieve this limit, any

flow of energy from the paint supply through

the paint line to the applicator electrode must

be prevented by grounding the paint line at

the applicator handle.

†

Verify that the applicator handle is ac-

tually grounded before operating it! This is

done with a fully connected and operational

system, by placing one lead of an ohmmeter

to the handle and the other to the building

electrical ground (cold water pipe, building

structure, steel, etc.). This reading should be

essentially zero.

†

If a greater reading is obtained, check that

the control unit is grounded. (See the control

unit manual for "Grounding Procedure".)

W A R N I N G

!

TYPICAL AA90 CLASSIC

APPLICATOR

INSTALLATION

Connect the low voltage cable to the control unit

low voltage socket. Gently hand tighten the cable

retaining nut.

Connect the outlet from a regulator supply switch

with air hose to the applicator using a wrench.

(The cascade unit uses reed switch triggering)

The control unit may be connected through conduit

with an explosion-proof switch on or near the spray

booth where it will be convenient to the operator,

or may be connected with a power cord depending

upon application requirement.