POWERING UP

CONTROL UNIT

(CASCADE UNITS)

When the AC power is turned on, the unit will

display the PC board applicator type number on

the kV setpoint display and the software revision

level in the µA display for 2-3 seconds.

Figure 23: Control Unit Start-Up Display

Description

Applicator Type

0

START-UP DISPLAY

85 kV Cascade

Changing the Setpoint at the

Applicator

To change the setpoint at the applicator, the ap-

plicator must NOT be triggered. By pushing the

kV button on the rear cover of the applicator, the

setpoint will change. If there are 2 green lights lit,

setpoint 1 is active. If 2 green lights and 2 yellow

lights are lit, setpoint 2 is active. If all lights are lit

(2 green lights, 2 yellow lights, and 2 red lights)

setpoint 3 is active.

kV to the applicator can be turned off by pressing

the applicator kV button in for 2-3 seconds. This

can be done whether the applicator is triggered

or not and is useful if the kV needs to be turned

off for spraying into recessed areas. When the

kV is disabled in this manner, the kV meter will

†

DO NOT turn the applicator off using the

applicator button in place of interlocking with

a solvent supply for flushing. The applicator

must be interlocked with solvent supply such

that when the solvent is on to flush the appli-

cator, there is no kV at the applicator.

W A R N I N G

!

Figure 26: View of Rear Cover

read zero, OFF will be displayed in the microamp

meter, and all kV setpoint indicator lights will be

disabled. Pressing the kV button in for another

2-3 seconds turns the kV to the applicator back on.

BASIC OPERATION

(CASCADE UNITS)

Triggering

High voltage is actuated by pulling the trigger

to start the flow of atomizing and fan control air

through the applicator. When the applicator is

triggered, a new switch in the applicator is ac-

tivated. The kV setpoint is displayed on the kV

display, the actual current draw on the µA display,

and the high voltage light illuminates. Under the

µA display is a bar graph meter that illuminates

according to the actual current draw.