Ransburg, Vector aa90 applicators - safety – Ransburg Vector AA90 79581 Classic User Manual

Page 8

Advertising
background image

AREA

Tells where hazards

may occur.

HAZARD

Tells what the hazard is.

SAFEGUARDS

Tells how to avoid the hazard.

Spray Area

General Use and

Maintenance

Electrostatic Arcing

Never operate the applicator without properly

grounding the following.

A. Operators

Operators must be grounded. Rubber soled

insulating shoes should not be worn. Grounding

leg or wrist straps may be used.

Operators must maintain contact with the handle

of the applicator. If work gloves are used, the

palm section must be cut out.

Operators must remove from themselves all

metal objects that are not grounded.

NOTE: REFER TO NFPA-33 REGARDING

OPERATOR GROUNDING OR SPECIFIC COUN-

TRY SAFETY CODE.

B. Parts being sprayed. Resistance between the

part and a grounded conveyor must not exceed

1 megohm.

C. Every metal and conductive object in the spray

area. This includes the booth, parts hangers,

fire extinguishers, conductive flooring, etc.

Grounded conductive flooring must be provided

in the spray area.

Turn off voltage at the power module before flush-

ing out, cleaning, or removing any parts from the

applicator.

Never install an applicator into a fluid system using

an isolated solvent supply.

Do not touch applicator electrode while applicator

is energized.

Improper operation or mainte-

nance may create a hazard.

Personnel must be properly

trained in the use of this equip-

ment.

Personnel must be given training in accordance

with the requirements of NFPA-33.

Instructions and safety precautions must be read

and understood prior to using this equipment.

Comply with appropriate local, state, and national

codes governing ventilation, fire protection, oper-

ation maintenance, and housekeeping.

Ransburg