Ransburg, Troubleshooting guide, Cont.) – Ransburg Vector AA90 79581 Classic User Manual

Page 48: Vector aa90 applicators - maintenance

Advertising
background image

General Problem

Possible Cause

Solution

Excessive Surging

Persistent Nozzle

Clogging

Paint Leaks

Through Center

of Nozzle

(Failure to Shut Off)

Paint Leaks Around

the Nozzle Cap

Paint Leaks At Rear

of Barrel

Orange Peel or

Rough Finish

Paint Runs or Has

Poor Hiding

Qualities

1. Restriction in pump air line

2. Insufficient pump capacity

3. Clogged paint filter

4. Low air volume capacity

5. Nozzle too large

1. Paint allowed to dry in

nozzle or line

2. Paint applicator filter too

coarse or damaged

3. Paint pigments too coarse

1. Loose nozzle cap

2. Improper trigger adjustment

3. Defective or dirty valve seat

1. Loose nozzle cap

2. Fluid seal worn

1. Loose packing nut

1. Evaporation rate too fast

2. Poor atomization

3. Viscosity too high

1. Low solids paint

2. Low viscosity

3. Excessive delivery

1. Remove restriction.

2. Secure larger pump or reduce output.

3. Service or replace.

4. Check factory air capacity.

5. Replace with correct nozzle.

1. Flush lines with solvent after each use.

2. Replace or change to finer screen paint filter.

3. Pre-filter paint and/or use larger nozzle orifice.

1. Tighten nut.

2. Readjust.

3. Flush out or replace as needed.

1. Tighten nut.

2. Replace seal.

1. Tighten packing nut.

1. Use slower evaporating solvent.

2. See "Poor Atomization and Distribution".

3. Add solvent or heat.

1. Use less solvent.

2. Use less solvent.

3. Use smaller nozzle, wider fan angle, lower

pump pressure.

(Continued On Next Page)

TROUBLESHOOTING GUIDE

(Cont.)

Ransburg

44

AH-07-01.9

Vector AA90 Applicators - Maintenance

Advertising
This manual is related to the following products: