Spray Tip Removal/Carbide

Removal

1. Remove the retaining nut completely by hand.

2. Remove the air cap from applicator by pulling

the air cap straight out from the applicator.

Figure 42a: Spray Tip Removal/Carbide Removal

Figure 42b: Spray Tip and Seal Removal

Figure 42c: Spray Tip Carbide Installation

Barrel Removal

1. Remove air cap and retaining ring.

2. With a flatblade screwdriver, remove trigger

screws and trigger.

3. Loosen the fluid tube barrel connection.

4. Using 19749 special wrench, remove barrel

nut.

5. Hold applicator handle, pull barrel straight out.

With Cascade units, the entire cascade assembly

will be removed. With Classic units, the resistor

tube housing will be left in the applicator handle.

3. Push the spray tip and holder out of the air cap

by pressing with a finger or soft object on the car-

bide or tapered portion of spray tip. The carbide

spray tip contains a removable nozzle seal with

or without a pre-orifice. The pre-orifice seal is

black, the standard seal is white. To remove the

sealfrom the tip holder, hold the end of the tip and

the end of the seal and snap apart the two pieces.

4. Locate the female opening of the tip holder on

the male portion of the 79642-00 tool as shown in

42c. Locate the tip holder in the air cap lining up

the slot in the tip holder with the pin in the air cap

(see figure 42c). With a light tap to the tool, the tip

holder will snap in place. Remove the 79642-00

tool from the assembly.

Vector AA90 Applicators - Maintenance

Ransburg

37

AH-07-01.9

5. Insert the seal into the tool as shown in figure

42d. Snap the seal into the tip holder.

Figure 42d: Seal Installation