background image

Figure 43: Barrel Removal

Barrel Disassembly

1. Using 76428 wrench, remove nozzle.

Figure 44a: Barrel Disassembly

Figure 44b: Barrel Disassembly

Needle Shaft Packing

Replacement

1. Remove spring spray retainer and lock nut from

shaft. Pull all rear seal parts off shaft. Replace

components as required.

Figure 45a: Needle Shaft Packing Replacement

2. Using 19749 special tool, remove packing nut.

3. Pull needle shaft assembly straight out.

Ransburg

38

AH-07-01.9