Vector AA90 Applicators - Operation

The green and yellow regions of the bar graph

meter indicate output current is in the optimum

range for maximum transfer efficiency. The red

region of the bar graph indicates high output current

causing decreased transfer efficiency.

The display at the rear of the applicator also

doubles as a microamp bar graph meter when

high voltage is on (see Figure 30). Its' function is

similar to that of the control unit bar graph display.

Figure 32: View of Applicator LED Display

Measuring "High Voltage On" Time

The 9060 Power Supply records the amount of

time the high voltage is triggered on up to 99,999

hours. These units are displayed in the kV and µA

displays of the unit. There are two registers that

retain this information, one that may be reset, the

Figure 33: Display In "High Voltage On" Time

Figure 31: µA Bar Graph Meter Display

other that is permanently retained in memory. The

number of hours the unit's high voltage has been

on may be displayed by depressing at the same

time the preset 1 and reset buttons. The display

will show hours of use for 3 seconds. This is the

re-settable register.

To reset this register, press the reset button while

the hours are displayed. Pressing the preset 2

and reset buttons at the same time will show the

number of hours on the non-re-settable register.

Local/Remote

The Vector product line is designed currently for

applicators only. The local/remote high voltage

control switch should be set to local for all Vector

applicator applications.

Figure 34: High Voltage Control Switch

†

The unit will not function if it is in remote

mode without external inputs.