Daily (or at start of each shift)

• Verify that ALL solvent safety containers are

grounded!

• Check within 20-feet of the point of operation

(of the applicator) and remove or ground ALL

loose or ungrounded objects.

• Inspect workholders for accumulated coating

materials (and remove such accumulations).

• Check that atomizer assembly is clean and

undamaged.

• Check the applicator electrode for damage.

• Clean the fluid filter, if necessary.

• Turn the control unit power ON. Its green pilot

should light or Aviator will be audible.

• Run a voltage output test.

Applicator High Voltage Output

Test (Cascade/Classic)

Use high voltage probe assembly (76652-01).

1. Set the meter dial to the kV scale. Plug the

high voltage probe into the side of the meter.

2. Attach the ground clamp to a proven earth

ground.

3. Make sure all grounded objects are at least

2-feet away.

†

Injury to personnel and damage to equip-

ment is probable if the ground clip is

NOT

ATTACHED. This step MUST be accom-

plished before voltage is applied.

W A R N I N G

!

4. Line up the hole in the test probe and the

electrode. Slide the test probe straight over the

electrode wire of the applicator.

5. Holding the metal portion of the high voltage

probe in your hand, trigger the applicator so voltage

exists at the electrode.

†

To provide proper equipment to operator

ground, the conductive handle of the probe

MUST be held in the bare hand of the op-

erator. To avoid a shock hazard, the meter

should

NEVER be disconnected from the

probe during high voltage contact.

W A R N I N G

!

6. Read the voltage displayed on the meter.

7. Turn the voltage to the applicator OFF, and

pull the test probe straight off the electrode.

Shutdown (or at end of shift)

1. Turn the control unit/power supply power OFF.

2. Turn the paint supply OFF.

3. Turn the shaping air supply OFF.

4. Wipe the applicator, cable, and hoses with a

rag and a suitable cleaning solvent.

5. Flush the fluid lines and applicator. Then bleed

the fluid pressure to zero, and allow the solvent

to remain in the lines (see “Flushing Procedures”

in this section).

6. Set the trigger stop lever.

Ransburg

34

AH-07-01.9

Vector AA90 Applicators - Maintenance