MAINTENANCE

SUITABLE SOLVENTS FOR

CLEANING VECTOR AA90

APPLICATORS

When cleaning the Vector AA90 applicator, a suit-

able solvent for cleaning depends on the part(s) of

the applicator to be cleaned and the material that

needs to be removed. Ransburg recommends

that all exterior cleaning be done with non-po-

lar solvents to prevent a conductive residue on

critical components. We also understand that

some of these solvents do not always meet the

cleaning needs of some materials. If conductive

polar solvents are used to clean the applicator

components, all residues must be removed using

a non-conductive non-polar solvent (i.e. high flash

naphtha). If there are any questions as to what

solvents are best for cleaning, contact your local

Ransburg distributor and/or your paint supplier.

ROUTINE SCHEDULE

Follow these maintenance steps to extend the

life of the applicator and ensure efficient opera-

tion.

Several Times Daily

• Turn the control unit power OFF!

• Set the trigger stop lever and inspect the air

cap for paint accumulation. Clean as frequently

as necessary with a soft bristled brush and a

suitable solvent.

• Clean all insulating surfaces in the system.

Remove paint accumulation from the exterior of

the applicator and low voltage or high voltage

cable with a solvent dampened cloth.

†

NEVER soak or submerge the electrical

components of the applicator, i.e., cascade

barrel assembly, assembly or cable assem-

bly. Damage and failure may occur.

C A U T I O N

!

†

ENSURE the power is OFF and the

system is grounded before using solvent

to clean

ANY equipment. Relieve all fluid

pressures.

†

When using cleaning solvent, standard

health and safety precautions should apply.

W A R N I N G

!

†

Cleaning of the exterior surfaces of the

applicator should be done with non-polar

solvents. If cleaning requires the use of po-

lar solvents, the applicator should be wiped

down with non-polar solvent prior to going

back into use.

C A U T I O N

!

†

Any solvent used for cleaning must have

a flash point of 5° C (9° F) above ambient

temperate. It is the end users responsibility

to insure this condition is met.

W A R N I N G

!

The AA90 applicator, air hoses, fluid hoses, and

low voltage/high voltage cable assemblies should

not be submerged or soaked in solvent. However,

the outer surface of these items can be wiped

with a suitable solvent. When the applicator is

disassembled into individual components, some of

these items may be soaked in a suitable cleaning

solvent. The items that cannot be soaked are noted

throughout this manual. All electrical components

cannot be cleaned or soaked in any solvents.