Weekly

• Check the entire system for damage, leaks,

and paint accumulation.

• Clean the atomizer assembly.

APPLICATOR ASSEMBLY

CLEANING PROCEDURE

Routine Cleaning

Equipment Needed

• An appropriate solvent

• Solvent safety container (grounded)

• Small soft-bristled brush

For efficient electrostatic operation, keep the ap-

plicator’s exterior and low voltage / high voltage

cable free of paint accumulation. This prevents

the loss of voltage to ground with a resultant re-

duction in transfer efficiency.

†

If production downtime is to be short,

the fluid lines may not require flushing

(depending on the coating material being

used). If the solids in the coating settle

slowly, the lines will not need to be flushed

as soon after shutdown as with fast set-

tling solids. The paint being used and the

length of downtime will determine the need

for flushing. Metallic paint and primer will

require flushing sooner than other types of

coating material.

NOTE

†

If the coating material is fast settling

and the fluid lines are not flushed soon

enough, the internal passages may be-

come clogged. This can lead to excessive

downtime for repair.

C A U T I O N

!

†

Before cleaning the nozzle assembly,

turn the control unit or power supply

OFF

and flush the fluid line with a compatible

solvent until clean. Turn the paint and air

supplies

OFF. Trigger the applicator to re-

lieve both fluid and air pressures.

C A U T I O N

!

FLUSHING

PROCEDURES

The fluid system should be thoroughly cleaned by

flushing with a clean compatible solvent whenever

a color change is made, or when the applicator

will not be used for an extended period.

1. Turn OFF the control unit/power supply power.

2. Turn the paint supply OFF.

3. Turn the shaping air supply OFF. Bleed all air

from the line.

4. Tilt the applicator down and trigger until it is

clear of paint.

5. Set the trigger stop lever and remove the nozzle

nut, air nozzle, and fluid nozzle.

6. Connect the solvent supply.

7. Release the trigger stop and run solvent through

the system until it runs clear.

8. Disconnect the solvent supply.

9. Trigger the applicator until it is clear of sol-

vent. After the preceding steps are complete, the

applicator is ready for color change, storage, or

maintenance.