TROUBLESHOOTING GUIDE

(Cont.)

General Problem

Possible Cause

Solution

Improper or No

High Voltage

Isolation System

Grounded Out

1. Faulty low voltage cable

connections

2. Improper or no ground at

control unit

3. Faulty barrel/cascade assembly

4. Faulty low voltage cable

5. Faulty control PC board

6. Dirty air cap and/or fluid nozzle

7. Blown fuse

8. Is the power turned on?

9. Is the atomizing air turned on?

10. Is the applicator triggered?

11. Is the applicator switch on?

12. Is the paint too conductive?

13. Faulty flow switch

1. Failed fluid hose

2. Isolation stand or charged

equipment too close to

ground

1. Check and secure at the applicator and at the

control unit.

2. Trace and correct.

3. Replace.

4. Replace.

5. Replace.

6. Clean as require per suggested "Maintenance

Schedule".

7. Replace fuse.

8. Check power supply.

9. Check air regulator.

10. Check applicator trigger.

11. Check applicator switch.

12. Check conductivity of paint.

13. Replace flow switch.

1. Replace fluid hose.

2. Provide adequate ground distance.