Position-data table (Field(s) within thick line must be entered.)
No. Position
Speed
Acceleration/
deceleration
Push Positioning
band
Acceleration
only MAX
0
* * * * * *
1 150
200
0.3
0
10
0
2
200
100
0.3 0 0.1 0
T1: 6 msec or more; time after selecting/entering a command position until the start input turns ON
(The scan time of the host controller must be considered.)
Note: When the start signal turns ON, the position complete output will turn OFF.
The start signal must be turned OFF with the confirmation that the position complete output
has turned OFF while the start signal remains ON.
T
1
T
1
Command position
Start
Position complete
Speed
Actuator movement
Position 1 Position 2