IAI America ERC User Manual

Page 60

Advertising
background image

40

3.7 Configuration

Using

Both SIO Converter and Insulated PIO Terminal Block


















































Note: Do not connect a teaching pendant and a PC at the same time. If both are connected at the

same time, a communication error (message level) will occur.

PERSONAL

COMPUTER

PC software

<RCB-101-MW>

Optional

Teaching pendant <RCA-T>

Optional

Cable length: 5 m

Host system <PLC>

SIO converter

Vertical <RCB-TU-SIO-A>
Horizontal <RCB-TU-SIO-B>

TB1

TB2

TB4

TB1




TB3

Connector

J1

A B

EMG

2

EMG

1

24V

0V

FG

ERC actuator

SIO converter

24-VDC control power supply

(Emergency-stop circuit)

24-VDC control/motor power supply (2 A or more)
Brake release switch
Motor-power cutoff circuit

Insulated PIO terminal block

TB2

RS232C crossed cable
(provided by the user)

Insulated PIO terminal block

NPN, vertical

<RCB-TU-PIO-A>

NPN, horizontal

<RCB-TU-PIO-B>

PNP, vertical

<RCB-TU-PIO-AP>

PNP, horizontal

<RCB-TU-PIO-BP>

Relay cable
Standard cable <CB-ERC-PWBIO * * *-H6>
Robot cable

<CB-ERC-PWBIO * * *-RB-H6>

Cable length: 1 m, 3 m, 5 m