3.5 Configuration Using a SIO Converter


If any of the following conditions applies, use a SIO converter to connect the teaching pendant, PC or PLC’s
communication module:
[1] The actuator’s rear cover cannot be reached and therefore the teaching pendant or PC cannot be connected.
[2] Want to execute movement operation or parameter edit for all axes when multiple axes are connected to the

single equipment.

[3] Want to operate the actuator via serial communication using the PLC’s communication module.









































Note: Do not connect a teaching pendant and a PC at the same time. If both are connected at the

same time, a communication error (message level) will occur.

PERSONAL

COMPUTER

PC software

<RCB-101-MW>

Optional

Teaching pendant <RCA-T>

Optional

Cable length: 5 m

Host system <PLC>

Relay cable
Standard cable
<CB-ERC-PWBIO * * *>
Robot cable
<CB-ERC-PWBIO * * *-RB>
Cable length: 1 m, 3 m, 5 m

 PIO

SIO

SIO converter
<RCB-TU-SIO-A>
<RCB-TU-SIO-B>

ERC actuator

24-VDC control/motor power supply (2 A or more)

Brake release switch

Emergency-stop/motor-power cutoff circuit

Drain wire

TB2

TB1

EMG

2

EMG

1

24V

0V

FG

B A

RS232C crossed

cable (provided

by the user)