10 incremental moves – IAI America ERC User Manual

Page 118

Advertising
background image

98

7.10 Incremental Moves


Example of use in operation) The actuator is caused to move from the home to the 30-mm position, from which

it will be moved repeatedly in increments of 10 mm. The travel speed from the
home to the 30-mm position is set as 100 mm/sec, and that for 10-mm
incremental moves is set as 20 mm/sec.


ERC controller








































P




L





C

[1]

[6]




[10] [8] [5] [3]

PIO

Signal name

Start

Command position 1

Command position 2

Command position 4

*Pause

Position complete

Home return completion


Zone

*Alarm

Category

Input








Output


Reference flow

Select/enter command position 1.

Start input ON

Movement to position 1 starts.

Position complete output OFF

Start input OFF

Position complete output ON

Select/enter command position 2.

Start input ON

Position complete output OFF

Start input OFF

Movement to the +10 mm position completes.

Position complete output ON

Movement to position 1 completes.

Movement to +10 mm from the current position starts.

[1]

[2]


[3]


[4]

[5]


[6]

[7]


[8]

[9]

[9] [7] [4] [2]

[10]

Advertising