9. Installation

9. Installation

This chapter explains how to install the actuator on your mechanical system.

9.1

General Rules on Installation

Follow the information below when installing the actuator, as a rule.
Do pay attention to these items (except when custom-order models).

: Possible

: Daily inspection is required x: Not possible

SA3
SA4
SA5
SA6

Installation posture

Horizontal installation Vertical installation Sideway installation Ceiling mount installation

Model

Vertical

Sideways

Ceiling mount

Horizontal

Caution:

1. When the unit is installed vertically oriented, attempt to put the motor up unless there

2. Can be installed sideways or ceiling mount, but the actuators must be checked

sbe slacked or displaced. If the actuator is used continuously while the stainless
sheet is slacked or displaced, the stainless sheet may break or other problems may
occur. Check the actuator daily and if the stainless sheet is found slacked or
displaced, make installation adjustment of the stainless sheet. [Refer to 13.9
Replacement (for models with slider cover).]

is a special reason. Putting the motor on the lower side would not cause a problem
in an ordinary operation. However, it may rarely cause a problem, when it is not
operated for a long period, depending on the surrounding environment (especially
high temperature), caused by the grease being separated and the base oil flowing
into the motor unit.

daily. If the actuator is installed sideways or ceiling mount, the stainless sheet may