Table 2 – general performance specifications – KB Electronics KBVF-23P User Manual

Page 15

Advertising
background image

15

Notes: 1. If a non-isolated signal is used, install the SIVFR – Signal Isolator (Part No. 9597). 2. Allows the motor to operate up to two times the
rated RPM. Constant motor horsepower will result when operating the drive in the “X2” mode above the motor rated frequency. 3. Dependent on
motor performance. 4. Do not operate the drive outside the specified AC line input voltage operating range.

Description

Specification

Factory

Setting

115 Volt AC Line Input Voltage Operating Range (Volts AC, 50/60 Hz)

115 (±15%)

208/230 Volt AC Line Input Voltage Operating Range (Volts AC, 50/60 Hz)

208 (–15%) / 230 (+15%)

Maximum Load (% Current Overload for 2 Minutes)

150

Carrier, Switching Frequency (kHz)

16, 8

Signal Following Input Voltage Range

1

(Volts DC)

0 – 5

Output Frequency Resolution (Bits, Hz)

10, 0.06

Minimum Speed Trimpot (MIN) Range (% Frequency Setting)

0 – 40

0

Maximum Speed Trimpot (MAX) Range (% Frequency Setting)

70 – 110

100

Acceleration Trimpot (ACC) and Deceleration Trimpot (DEC/B) Range (Seconds)

0.3 – 20

1.5

Boost Trimpot (DEC/B) Range (50 Hz Only) (Volts/Hz)

0 – 30

5

Slip Compensation Trimpot (COMP) Range at Drive Rating (Volts/Hz)

0 – 3

1.5

Current Limit Trimpot (CL) Range (Amps AC): KBVF-21D

0.65 – 1.8

1.6

KBVF-22D

1.0 – 2.8

2.4

KBVF-13, 23, 23D, 23P

1.5 – 4.5

3.8

KBVF-14, 24, 24D, 24P

2.5 – 7.5

6.4

KBVF-26D

3.5 – 10.5

8.8

Motor Frequency Setting (Hz) (Jumper J1)

50, 60

60

Output Frequency Multiplier (X1, X2) (Jumper J2)

2

1, 2

1

Minimum Operating Frequency at Motor (Hz)

0.3

Speed Range (Ratio)

60:1

Speed Regulation (30:1 Speed Range, 0 – Full Load) (% Base Speed)

3

2.5

Overload Protector Trip Time for Stalled Motor (Seconds)

6

AC Line Input Undervoltage/Overvoltage Trip Points for 115 Volt AC Line (±5%) (Volts AC)

4

76 – 141

AC Line Input Undervoltage/Overvoltage Trip Points for 208/230 Volt AC Line (±5%) (Volts AC)

4

151 – 282

Operating Temperature Range (°C / º F)

0 – 45 / 32 – 113

TABLE 2 – GENERAL PERFORMANCE SPECIFICATIONS