12.1 Power On (PWR) – The “PWR” LED will illuminate green when the AC line is applied to the drive.

12.2 Status LED (ST) – The “ST” LED is a tricolor LED which provides indication of a fault or

abnormal condition. The information provided can be used to diagnose an installation problem

such as incorrect input voltage, overload condition, and drive output miswiring. It also pro-

vides a signal which informs the user that all drive and microcontroller operating parameters

are normal. Table 4, on page 38, summarizes the “ST” LED functions.

Note: The drive is factory set to the Automatic Start Mode. For Manual Start/Rest, see

Section 9.6, on page 33.

13 TRIMPOT ADJUSTMENTS

The drive contains trimpots which are factory set for most applications. See Figure 4, on page 20,

for the location of the trimpots and their approximate factory calibrated positions. Some applications

may require readjustment of the trimpots in order to tailor the drive for a specific requirement. The

trimpots may be readjusted as described below.

WARNING! If possible, do not adjust trimpots with the main power applied. If

adjustments are made with the main power applied, an insulated adjustment tool

must be used and safety glasses must be worn. High voltage exists in this drive.

Fire and/or electrocution can result if caution is not exercised. Safety Warning, on pages 8

and 9, must be read and understood before proceeding.