FIGURE 21 – ENABLE SWITCH CONNECTION

Jumper Removed

Connector Installed for

Forward Enable Switch

Connector Installed for

Reverse Enable Switch

CON2

F - S - R

(Close to Run)

Red *

(Open to Stop)

Black

White

Enable Switch

CON2

Forward

(Close to Run)

Red

(Open to Stop)

Black

White*

Enable Switch

CON2

Reverse

*For Forward Enable Switch connection, the red wire is not used. For Reverse Enable Switch connection, the white wire is

not used. The unused wire must be insulated or it may be cut off at the connector.

9.7

Forward-Stop-Reverse

Switch Connection (CON2) –

To operate the drive using a

Forward-Stop-Reverse Switch,

remove the factory installed

jumper on CON2 and install

the 3-wire connector (sup-

plied). CON2 is located on the

lower PC board. The connec-

tor must be wired to a “main-

tained” switch or contact. See

Figure 20. Also see Forward/Reverse Speed Selection, in Section 6.4, on page 27.

Note: The drive can be factory programmed for momentary contact operation.

FIGURE 20 – FORWARD-STOP-REVERSE SWITCH CONNECTION

Jumper Removed

Connector Installed for

Forward-Stop-Reverse Switch

CON2

F - S - R

Forward-Stop-Reverse

Black

White

CON2

Red

Stop

Forward

Reverse

Switch