KB Electronics KBVF-23P User Manual

Page 23

Advertising
background image

5.1

Removing the Finger-Safe Cover – The Finger-Safe Cover may have to be removed before

wiring the drive or setting selectable jumpers. All trimpots can be readjusted with the Finger-

Safe Cover installed. Notice the orientation of the Finger-Safe Cover before removing it.

Note: The Finger-Safe Cover (except that of the KBVF-21D) is designed with a removable

panel (on the trimpots side) which must be removed for installation of optional accessories

SIVFR Signal Isolator and Run/Fault Relay (Part No. 9597) or Multi-Speed Board (Part No.

9503). Complete instructions are provided with the accessories.

Model KBVF-21D – Designed with three “push-ins” (instead of retainer clips) located where

the Finger-Safe Cover aligns with the base. To remove the cover, gently press at the three

push-ins until the cover disengages from the base.

Models KBVF-22D, 13, 23, 23D, 23P 14, 24, 24D, 24P, 26D – To remove the Finger-Safe

Cover, gently lift up on the four retainer clips until the cover disengages from the base. See

Figures 2B and 3A, on pages 17 and 18.

Note: On Model KBVF-26D, the inner bus capacitor support bracket should not be removed.

5.2

Installing the Finger-Safe Cover – To install the Finger-Safe Cover, be sure to properly align

the retainer clips or push-ins. Gently push the Finger-Safe Cover onto the base until the

retainer clips or push-ins are fully engaged with the base.

6

SETTING SELECTABLE JUMPERS

The drive has customer selectable jumpers which must be set before the drive can be used. For the

location of jumpers, see Figure 4, on page 20.

23

Advertising