KB Electronics KBDF-48 User Manual

Page 14

Advertising
background image

14

TABLE 2

GENERAL PERFORMANCE SPECIFICATIONS

Description Specification

Factory

Setting

115 Volt AC Line Input Operating Range
(Volts AC, 50/60 Hz)

115 (± 15%)

──

208/230 Volt AC Line Input Operating Range
(Volts AC, 50/60 Hz)

208 (-15%) / 230 (+15%)

──

400/460 Volt AC Line Input Operating Range
(Volts AC, 50/60 Hz)

380 (-15%) – 460 (+15%)

──

Maximum Load
(% of Current Overload for 2 Minutes)

150

──

Switching Frequency
(kHz)

8, 10, 12, 14, 16

8

Voltage Following Signal Input Range
(Volts DC)

0 – ±5, 0 ±10

0 – 5

Current Following Signal Input Range
(mA DC)

4 – 20, 0 – 20

──

PWM Following Signal Input Range
(kHz / % Duty Cycle)

0.15 – 1 / 0 - 100

──

Analog Output
(Volts DC)

0 – 5

──

Output Frequency Resolution
(Hz)

0.06

──

Minimum Operating Frequency at Motor
(Hz)

0.3

──

Acceleration Time
(Seconds)

0.1 – 180.0

1.5

Deceleration Time
(Seconds)

0.3 – 180.0

1.5

Speed Range
(Ratio)

50:1

──

Speed Regulation (30:1 Speed Range, 0 – Full Load)
(% Base Speed)

1

2.5

──

Overload Protector Trip Time for Stalled Motor (Seconds)

6

──

115 Volt AC Line Input
Undervoltage/Overvoltage Trip Points (± 5%) (Volts AC)

2

76 – 141

──

208/230 Volt AC Line Input
Undervoltage/Overvoltage Trip Points (± 5%) (Volts AC)

2

151 – 282

──

400/460 Volt AC Line Input
Undervoltage/Overvoltage Trip Points (± 5%) (Volts AC)

2

302 / 567

──

Multi-Function Relay Output Contact Rating
(Amps at 30 Volts DC, 125 Volts AC, 250 Volts AC)

1, 0.5, 0.25

──

Operating Temperature Range
(°C / °F)

0 – 40 / 32 – 104

──

Operating Humidity Range
(% Relative, Non-Condensing)

0 – 95

──

Storage Temperature
(°C / °F)

-25 – +85 / -13 – +185

──

Notes: 1. Dependent on motor performance. 2. Do not operate the drive outside the specified
AC Line input voltage operating range.

Advertising
This manual is related to the following products: