FIGURE 38

FLOW CHART TO CHANGE SET FREQUENCY FROM 5.00 Hz TO 43.21 Hz*

(DRIVE IN STOP MODE)

RUN

STOP

*If Function 2.02 is set to "0000", frequency change requires pressing the ENTER Key.
Throughout this sequence, you must proceed to the next step within 20 seconds, before the
"Press Enter Key" step, or the display will revert back to "0500". The new value will be stored in
Function 3.00.