KB Electronics KBDF-48 User Manual

Page 23

Advertising
background image

23

Models KBDF-23D, 24D, 27D: Designed for 115 and 208/230 Volt 1-phase AC Line input. For
115 Volt Line input, connect the AC Line input hot lead to Terminal "L1" and the neutral lead to
Terminal "N". For 208/230 Volt AC Line input, connect to Terminals "L1" and "L2". See Figure 8.

Note: 230 Volts AC will be applied to the motor with 115 Volt AC Line input.

FIGURE 8

MODELS KBDF-23D, 24D, 27D

AC LINE AND GROUND CONNECTIONS



Models KBDF-23, 23F, 24, 24F, 27, 27F:
Designed for 208/230 Volt 1-phase AC Line input.
Connect the AC Line input to Terminals "L1" and
"L2". See Figure 9.






Models KBDF-23P, 24P: Designed for 208/230
Volt 3-phase AC Line input. Connect the AC Line
input to Terminals "L1", "L2", and "L3". See Figure
10.





Models KBDF-27P, 29: Designed for 208/230 Volt 1-Phase and 3-Phase AC Line Input.
Connect the 1-Phase AC Line Input to Terminals "L1" and "L2". Connect the 3-Phase AC Line
input to Terminals "L1", "L2", and "L3". See Figure 11.

FIGURE 11

MODELS KBDF-27P, 29

AC LINE AND GROUND CONNECTIONS

FIGURE 9

MODELS KBDF-23, 23F, 24, 24F, 27, 27F

AC LINE AND GROUND CONNECTIONS

FIGURE 10

MODELS KBDF-23P, 24P

AC LINE AND GROUND CONNECTIONS

Advertising