Specifications – LEESON FHP Series NEMA 4x Variable Speed Drive User Manual

Page 10

Advertising
background image

1

Specifications

1-Phase

1 or 3-Phase

Max Continuous

AC

Input

Output

Max

Output

Amps

Drive

(VAC)

(VAC)

HP

Current (AC)

In

175326.00 *115/230 230 1 4.0 14/7

*

Connect only 115 VAC line input to the 115 VAC terminals. Application of 230 VAC line input when set for 115
VAC will result in severe damage to the motor and drive, and possible explosion and injury.

† Derate current by 2% per degree if the operating temperature is above 40°C. Under no circumstances may the

ambient temperature exceed 55° C.

AC Voltage Input Range 115/230 VAC ± 10%, 50/60 Hz single phase
Standard Carrier Frequency

16 KHz

Output Frequency Range

0 – 120 Hz

Maximum Output Frequency Range

30 – 120 Hz

Minimum Output Frequency Range 0 – 30 Hz
Acceleration Time Range

1 – 12 seconds

Deceleration Time Range

1 – 12 seconds

Analog Input Voltage Range

0 – 5VDC,0-10VDC,4-20mA**

Input Impedance, S1 to S2

~ 100K ohms

Braking Current

0-100% rated output

Braking Time

1 – 12 seconds

Vibration

0.5G max (20 – 50 Hz)

0.1G max (> 50 Hz)

Weight

1.2 lb

Ambient Operating Temperature Range

10° – 40° C

** Isolation is standard, and allows for non-isolated speed input, enable and direction switch inputs to be used.

Advertising