16

Motor connections

Motor connections are made to TB502

Single-phase operation

For single-phase operation, connect the motor as shown

below in Figure 7. Ensure that the prewired capacitor and

its associated motor coil are connected to terminals U and

V as shown. This connection may be internal if using a 2-

wire motor. If the motor has three leads, you must make

this connection yourself.
To reverse a single phase permanent split capacitor motor,

connect the motor as shown in Figure 8 (page 17). The

motor cap must be removed from the circuit.

Figure 7. Single Phase Operation (pre-wired cap)

DO NOT use a direction

switch with this setup