background image

38

Application Notes

Independent adjustable speeds with DIR switch

Replace the speed adjust potentiometer with two single-
pole multi-position switches, and two or more
potentiometers in parallel, with a total parallel resistance of
10K ohms. Figure 17 below shows the connection of two
independent speed adjust potentiometers that can be
mounted at two separate operating stations.

E2

E1

S1

S2

D (DIRECTION)

S3

FORWARD

REVERSE

TB501

REVERSE

SPEED

FORWARD

SPEED

20K OHM

20K OHM

Figure 17. Independent Adjustable Speeds