In addition to standard 3-phase induction motors, the
following motor types may be used with the FHP Series:

• Permanent split capacitor (PSC)
• Shaded pole
• AC synchronous

Warning

Caution should be taken when operating fan-cooled
motors at low speeds because their fans may not
move sufficient air to properly cool the motor. LEESON
recommends “inverter-duty” motors when the speed
range is beyond 10:1.

ƽ

The following motor types MAY NOT be used:

• Split phase
• Capacitor start
• Repulsion induction
• Series Universal AC/DC
• Any motor with starting switch (centrifugal or relay)

and/or separate starting winding.