23

Voltage Doubler

The 175326.00 series drives are equipped with a
unique voltage-doubling feature, for use when 230 VAC
input voltage is not available. This feature converts a 115
VAC input to a 230 VAC output, for use with 230V motors.
The drive output current rating remains the same for either
AC input voltage.

Refer to Figure 6 (page 15) for connection information. Use
extreme caution when connecting this feature. Incorrect
use of this feature may result in fire and/or serious injury.

NOTE: The 175326.00 is meant to be used with 208/230
VAC motors only. DO NOT use this series of drives with
115 VAC motors.

Warning

DO NOT connect 230 VAC line input when drive is
set for 115 VAC input.
This will result in severe
damage to the motor and drive, and possible
explosion or severe injury.