50

Optional Capacitor Kit (

175325.00)

LABEL ON CAPACITOR

FREQUENCY

VALUE

3n3J

12kHz

0.0033uF

6n8

10kHz

0.0068uF

10n

8kHz

0.01uF

33n

4kHz

0.033uF

See Figure 22 for Capacitor locations and installation
instructions

In some applications, lowering carrier frequency reduces
switching losses and increases bearing life in some motors.
LEESON

provides an optional capacitor kit for lowering the

carrier frequency.

The default carrier frequency on FHP Series controls is
16kHz.

Using one of the capacitors supplied in the kit, the

carrier

frequency can be lowered to a range of 12kHz to 4kHz.

Note: Audible noise will increase when the carrier
frequency is lowered.

To lower the carrier frequency on all FHP Series controls,
install

one of the following 2-pin capacitors on the board: