LEESON SM Series Sub-Micro Inverters User Manual

Page 23

Advertising
background image

19

11.4

PRESET SPEEDS AND SPEED POT
(WITH TWO-WIRE START/STOP CONTROL)

NOTES:

1.

For preset speed control, all or some of the TB-13 terminals must be programmed as preset
speed selects. If only two or three preset speeds are required, only two of the TB-13 terminals
must be used. Refer to the table in the description of Parameters 31-37 in Section 15.0.

2.

Program the PRESET SPEEDS (Parameters 31-37) to the desired values.

3.

If speed pot control is desired when none of the preset speeds are selected (all preset speed
selects are open to TB-11), set STANDARD SPEED SOURCE (Parameter 05) to 0-10 VDC
(03).

1

2

5

6

11

13A

13B

13E

25

16

17

MAINTAINED

RUN/STOP

CONTACT

SPEED

POT

FORM A

RELAY

RUN

SIGNAL COMMON

0-10 VDC INPUT

SPEED POT POWER SUPPL

Y

DIGIT

AL INPUT REFERENCE

TB-13A FUNCTION SELECT

(PRESET SPEED #1)

TB-13B FUNCTION SELECT

(PRESET SPEED #2)

TB-13E FUNCTION SELECT

(PRESET SPEED #3)